Akulon® K222-KGV6


Polyamide 6
DSM Engineering Plastics

General
Material Stayus • Commercial: Active
Literature • Technical Datasheet (English)
UL Yellow Card • E47960-100627642
Search for UL Yellow Card • DSM Engineering Plastics
• Akulon®
Availability • Asia Pacific
Filler/Reinforcement • Glass Fider Reinforcement, 30% Filler by Weight
Additive • Flame Retardant • Heat Stabilizer
Features • Flame Retardant
• Halogen Free
• Heat Stabilized
• Low (to None) Phosphorus Content
Phisical Nominal Value Unit Test Method
Density 1.45 g/cm3 ISO 1183
Molding Shrinkage
­ ­ Across Flow
­ ­ Flow
­
0.90%
0.55%
ISO 294-4
­
­
Water Absorption
­ ­ Saturation, 23°C
­ ­ Equilibrium, 23°C, 50% RH
­
5.6%
1.5%
ISO 62
­
­
Mechanical Nominal Value Unit Test Method
Tensile Modulus 7200 MPa ISO 527-2
Tensile Stress (Break) 85.0 MPa ISO 527-2
Tensile Strain (Break) 3.7% ISO 527-2
Impact Nominal Value Unit Test Method
Charpy Notched Impact Strength (23°C) 4.0 kJ/m2 ISO 179/1eA
Charpy Unnotched Impact Strength (23°C) 43 kJ/m2 ISO 179/1eU
Thermal Nominal Value Unit Test Method
Heat Deflection Temperature
­ ­ 1.8 MPa, Unannealed
­
180°C
ISO 75-2/A
­
Melting Temperature 220°C ISO 11357-3
Electrical Nominal Value Unit Test Method
Comparafive Tracking Index 525 V IEC 60112
Flammability Nominal Value Unit Test Method
Flammability Classification
­ ­ 0.800 mm
­ ­ 1.60 mm
­
V-2
V-2
IEC 60695-11-10, -20
­
­
Glow Wire Flammability Index
­ ­ 0.750 mm
­ ­ 1.60 mm
­
960°C
960°C
IEC 60695-2-12
­
­
Glow Wire Ignition Temperature
­ ­ 0.750 mm
­ ­ 1.60 mm
­
725°C
725°C
IEC 60695-2-13
­
­

.

- - . (044)408-34-64, (044)451-52-41

E-mail: info@polygon-ltd.com